MFP 1000

MFP 1000

MFP system

Fast and okonomical quality control and development of flat media with dust, oil or salt starting at 120 nm. Versions MFP 1000 HEPA for EN 1822-3 and ISO 29463-3

Benefits
Description
Application

Benefits

  • Particle size measurements from 120 nm
  • Internationally comparable measurement results
  • Widespread distribution of the measurement system
  • High reproducibility of the testing method
  • Easy use of different test aerosols, e.g. SAE Fine and Coarse, NaCl/KCl, DEHS
  • Flexible filter test software FTControl
  • Sequence programs for pressure loss measurements, measurements of fraction separation efficiency and burden measurements
  • Easy to operate; even untrained personnel can be instructed quickly in the use of the equipment
  • Short set-up times
  • Cleaning and calibration can be performed autonomously by the customer
  • Easy use of the measurement technology components – even in other applications
  • Mobile setup, easy to move on castors
  • Reliable operation
  • Validation of the clear function of individual components and the overall system during pre-delivery acceptance testing and upon delivery
  • Low-maintenance
  • The unit will reduce your operating costs

Description

MFP 1000 Filtermedienprüfstand

Fig. 1: MFP 1000

MFP filter test rigs from Palas® have already proved themselves many times over all around the world in practical applications in development and quality control.

The MFP filter test rig is a modular filter testing system for flat filter media and small mini-filters. The MFP 1000 can be used to determine:

  • pressure loss curve on the medium without a dust coating,
  • fraction separation efficiency, or
  • burden and fraction separation efficiency during application of the burden

within shortest times – reliably and therefore cost-effectively.

The corresponding aerosol generator can be used depending on the standard or application.

With the aid of the new light scattering spectrometer Promo® 1000, clear and reliable determination of the aerosol concentration and the particle size and therefore a clear determination of the fraction separation efficiency can be ensured.

The largely automated setup of the test sequence together with the clearly defined individual components and the individually adjustable sequence programs of the filter test software FTControl combine to deliver the high reliability of our measurement results.

As a result, filter tests can be performed quickly and easily with the different test aerosols.

Our quality in detail

MFP 1000 Filtermedienprüfstand mit Nummern.jpg

Fig. 2: MFP 1000

1. Variable aerosol generation Thanks to the use of different dispersers for dusts, KCl/NaCl, DEHS etc.; shortened measurement times are possible e.g. through increased dust concentration

2. Corona discharge (optional) – adjustable ion stream for different mass flows. Mixed air, adjustable for inflow speeds from 0.05 to 1 m/s. Optional: Transient inflow.

3. Mobile pneumatic filter holder for fast removal and loading of the test rig.

4. Light scattering spectrometer Promo® system for clear particle measurements in high concentrations of up to 5 • 105 particles/cm3 (SAE Fine) with integrated Windows test rig software. Easy to operate even for untrained personnel thanks to the automated sequence programs for performance of the filter testing. The test rig can be controlled fully automatically.

Automation

The MFP 1000 has integrated mass flow controllers that it uses to control the volume flow; these can be automatically monitored and controlled via the FTControl filter test software. The integrated sensor data such as the volume flow and differential pressure at the filter are also recorded automatically during the filter test.

Measurement of the fraction separation efficiency

Vergleich von Fraktionsabscheidegraden.png

Fig. 3: Example: Comparison of fraction separation efficiencies

  • Clear demonstration of the separation efficiency of your filter medium throughout the entire measurement range from 0.12 µm to 40 µm with the Promo® system
  • With its maximum sensitivity, the particle measurement technology can highlight even fine differences in separation efficiency.
  • Short measurement times of around 2 minutes per separation efficiency measurement thanks to optimized aerosol application
  • Simple comparison of separation efficiency curves, calculation of mean values also possible

Sampling and layout

The strictly vertical layout of the MFP 1000 test system with just one sampling probe delivers clear measurements even for larger particles of up to 40 µm, as sedimentation losses can be ruled out. This enables reliable determination of the separation efficiency across the entire measurement range for all particle sizes.

Burden / hold time measurement and record of the pressure loss curve

Standzeitmessung.png

Fig. 4: Example: Hold time measurement

  • Performance of measurements of the fraction separation efficiency during dust application; pressure loss or measurement time can be pre-selected as the abort criterion
  • Determination and representation of the pressure loss curve and retention curve in diagram and table form The representation of the particle diameters at 80% and 95% separation efficiency provides additional information.
  • Comparison of the fraction separation efficiencies during the different burdening steps
  • Shortening of the measurement times, e.g. through increased dust concentration

Aerosol generator of your choice

  • RBG 1000
  • AGK 2000 with drying length
  • PLG 1000

Application

  • For filter media and small mini-filters
  • product development and during production monitoring
  • Fast and cost efficient testing of fractional efficiency with dust, oil or salt based on ISO 11155-1 (cabin air filters), ISO 5011 (engine pre-air filters), EN 779/ Ashrae 52.2/ ISO 16890 (room air filters),
  • Within the version MFP 100 HEPA measurement of MPPS of HEPA/ ULPA filter media based on EN 1822 and ISO 29463-3

To enquire about the MFP 1000 MFP system and the options available contact us now.

"*" indicates required fields

*
This field is for validation purposes and should be left unchanged.

Newsletter Subscription

Stay up to date with Filter Integrity Ltd

  • This field is for validation purposes and should be left unchanged.